DO'S & DONT'S
MILOS
INSTALLATION PROCESS
Rointe underfloor heating systems have been designed so that installation is quick and easy, but as with all electrical
systems, certain procedures must be followed. It is important to ensure that you have the correct heating mat(s) for the area
you wish to heat and thoroughly read these recommendations about installation.
The installation of these underfloor heating systems is only
recommended under ceramic, quarry or natural stone tiles. The
maximum thermal resistance of the installed floor must not exceed
0.15 [m²K / W].
It is also possible (but not recommended) to install the heating element
under floor finishes such as wood or vinyl by applying a self levelling
compound over the heating mat. You must ensure that all heating
cables are completely covered with a minimum of 10 mm self levelling
compound. It is important that the levelling compound is suitable for
use with underfloor heating.
Note that delicate floor finishes such as wood or vinyl have a maximum
floor surface temperature of 27°C. This temperature must NOT be
exceeded.
130 · Rointe efficient heating